NASHIRA Series – HIGH-EFFICIENCY ENTHALPY RECOVERY UNITS

Specification

Operating range

Nominal airflow of 150 to 200 m³/h at 300 Pa static pressure

Application

- Air renewal in single family houses and apartment buildings. Ensures a comfortable,

healthy and energy-efficient indoor climate.

- High efficiency exchanger core

- Counterflow heat and moisture exchanger with up to 88% sensible efficiency and 72% latent efficiency.

High efficiency Fans

ABS volute forward centrifugal fan with galvanized steel material wheel blades in with low noise,

single-phase EC motor.

Filtration

- ISO ePM2.5 83% filters (F7) or ISO ePM2.5 91% filters (F9) are used on the supply air side.

- ISO Coarse 65% filter (G4) is used on the extract air side.

Bypass

100% fresh air bypass integrated with manual and automatic control. The bypass is particularly useful

when the indoors temperature is higher than outdoors and free cooling is preferable.

Control

An integrated function control, located inside the electrical box and wired to all the components (fans,

bypass, temperature and humidity probes, etc.). Includes control terminal for remote control which allows

manual and automatic fan control.

Other

Single-phase electrical supply 230V 50Hz.

Accessories

Filters accessories

Ducting accessories

          Flow rate: 15 or 30 m3/h. (To be installed inside the duct)

          (To be installed inside the cuff of the BDOP inlets)

          Equipped with 4 PLUGSK nozzles 90/75 able to accept up to a total of 8.

          up to a maximum of 8 outlets for dry areas (dining room, living room, bedrooms) Ø 80 mm.

ELECTRICAL ACCESSORIES